Temperature dependence of the luminescence decay in the fluorescent dyes

Authors

  • Saksit Sukprasong
  • Tanabat Promjun Faculty of Science at Si Racha, Kasetsart University Si Racha Campus, Chon Buri 20230
  • Athipong Ngamjarurojana Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200

Abstract

      The main aim of this study was to use laser induced fluorescence (LIF) technique to study and compare the temperature dependence of the luminescence decay curves of the fluorescent dyes; such as green dye, orange dye, and red dye. The 470 nm blue laser was used as an excitation light source to induce fluorescence. The LIF spectra were detected by a compact fiber coupled BTC-110S CCD spectrometer. All the controls and data acquisition were performed under a computer interfacing software. It was found from the experiment that the fluorescence spectra off fluorescence dyes possess temperature dependent properties, for both peak intensity and spectrum peak-value. The fluorescent intensity decreases at higher temperature for all the samples under the investigation for the range of 25–55 oC and the orange dye was found to be the most temperature sensitive for this temperature range.

Author Biographies

Saksit Sukprasong

Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200

Tanabat Promjun, Faculty of Science at Si Racha, Kasetsart University Si Racha Campus, Chon Buri 20230

Faculty of Science at Si Racha, Kasetsart University Si Racha Campus, Chon Buri 20230

Athipong Ngamjarurojana, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200

Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200

References

1.Burt , M.C. and Dave, B.C. (2005). An optical temperature sensing system based on encapsulation of a dye molecule in organosilica sol–gels. B.C. Sensor. Actuator. B, 107, 552-566.
2.Mills, A. and Lepre, A. (1999). Development of novel thermochromic plastic films for optical temperature sensing. Analyst, 124, 685-689.
3.Mills, A., Tommons, C., Bailey, R.T., Tedford, M.C. and Crilly, P.J. (2006). Luminescence temperature sensing using poly(vinyl alcohol)-encapsulated Ru(bpy)32+films. Analyst. 131, 495-500.
4.Liu, T., Campbell, B., Burns, S.P. and Sullivan, J.P. (1997). Temperature- and pressure-sensitive luminescent paints in aerodynamics. Appl. Mech. Rev. 50, 227-246.
5.Gallery, J., Gouterman, M., Callis, J. and Khalil, G. (1994). Luminescent thermometry for aerodynamic measurements. Rev. Sci. Instrum. 65, 712-720.
6.Campbell, B., Liu, T., Burns, S.P. and Sullivan, J.P. (1997). Rotor blade pressure measurement in a high speed axial compressor using pressure and temperature sensitive plants. AIAA Paper. 94, 6-9.
7.Kolodner, P. and Tyson, J.A. (1983). Remote thermal imaging with 0.7-µm spatial resolution using temperature-dependent fluorescent thin flims. Appl. Phys. Lett. 42, 117-119.
8.Khalil, G.E., Lau, K., Phelan, G.D., Carlson, B., Gouterman, M., Callis, J.B., et al. (2004). Europium beta-diketonate temperature sensors: Effects of ligands, matrix, and concentration. Rev. Sci. Instrum. 75, 192-206.
9.Mitsuishi, M., Kikuchi, S., Miyashita, T., Amao, Y. and Mater, (2003). Characterization of an ultrathin polymer optode and its application to temperature sensors based on luminescent europium complexes. J. Chem. 13, 2875-2879.
10.Guilbault, G. G. (1990). Plactical Fluorescence (2th ed.). New York: Marcel Dekker.
11.Pantke, E.R. and Labhart, H. (1972). On the temperature dependence of non-radiative deactivation processes. Chemical Physics Letters.16, 255-259.

Downloads

Published

2014-06-05

Issue

Section

Research Article